+86 512 66576317
搜索

Hydrogen Circulation Pump Test Bench

Product Introduction


The hydrogen circulation pump is a key component in the hydrogen fuel cell vehicle. It can re-transport the hydrogen that has not fully reacted in the stack to the stack inlet, thereby improving the utilization rate of hydrogen. The hydrogen circulating pump test bench is a special testing equipment for the performance and durability test of the hydrogen circulating pump.

 

The test bench can test parameters such as pressure, flow rate, temperature, humidity, speed, voltage, current, etc., and can carry out the test items that must be verified for the development of hydrogen circulating pump according to the set procedures and test conditions. It is designed to test whether the performance indicators of the circulating pump meet the needs of use when running under various working conditions.

 

The test bench can be equipped with high and low temperature environmental boxes and silent boxes according to user needs, which can simulate the actual vehicle operating conditions of the hydrogen circulating pump in an all-round way. It is an essential test equipment in the development and production of hydrogen circulating pumps.

 

Test Item

 

Routine Test

Performance Test

Low Voltage Electrical Test

Reliability Test

Low temperature working test

Full power working voltage range test

DC supply voltage test

 

 

 

 

 

 

 

 

Reliability test

High temperature working test

Power limited working voltage range test

Low voltage power supply overvoltage test

Storage temperature test

Maximum working speed test

MCU low voltage power supply ramp up/down test

Humidity test

Maximum output pressure test

Instantaneous power interruption test

Temperature cycle test

Maximum gas flow test

Start (surge) test

Ice breaking start test

System efficiency test

Low pressure reverse test

Noise test

Rated power test

Open circuit test

Tightness test

Peak power and duration test

Locked-rotor protection test

 

Test Curve

 


Features

 

1) The use of segmented adjustment and measurement technology realizes a wide range of pressure adjustment and flow measurement, which can meet the testing needs of most hydrogen circulating pumps on the market;

2) Applicable to a variety of test media (including air, nitrogen, helium, hydrogen), providing users with more flexible and diverse test methods;

3) The main pressure control system adopts electric proportional valve control, with high control precision, fast response and stable performance;

4) The control software has complete functions, convenient and flexible parameter setting, which can meet the different test needs of users, and has good adaptability;

5) It has complete safety interlock, fault protection function, abnormal alarm function, and real-time monitoring of temperature, pressure, flow and other information through industrial computer;

6) Using computer to automatically control the test process and process test data, it can automatically draw test curves such as pressure, flow rate, speed, voltage, current, etc., automatically judge test results, save test data and print test reports, and can query test result data through various search conditions .

 


Technical Parameter

Project Name

Range

Precision

Pump inlet pressure

0-10 bar

0.1FS

Pump outlet pressure

0-10 bar

0.1FS

Differential pressure adjustment before and after the pump

 

4-40Kpa

 

/

Small flow

0-30Nm3/h

±1FS

Large flow

0-150Nm3/h

±1FS

Noise test

30-130dB(A)

IEC61672-level 1

Voltage measurement

75VDC

±0.2FS

Current measurement

100ADC

±0.1FS

High and low temperature chamber

-50-150℃

≤1℃